BoQ assemblies
A few sizes of a piece of work give every item that goes with it: a wall its walling, plaster, paint and DPC; a strip foundation its trench to its disposal; a length of road every layer. The formulas, how the items are found in the BoQ, and the firm's own assemblies.
An assembly turns a few sizes typed on the BoQ into the quantities of every item that goes with that piece of work, as a QS works them out on dimension paper. No drawing is needed (on a drawing, the take-off has its own assemblies). Each quantity is written into its item's dimensions with its working, so Explain a quantity shows how it was reached.
Add work from an assembly
- 1In the BoQ editor press From an assembly (foot of the sheet).
- 2Choose the kind of work and the assembly; type where it is (e.g. Wall W1, ground floor), how many identical, and its sizes. Each size comes with its usual value.
- 3Press Work Out the Items: each item with its working (12.5 x 3 - 3.6) and quantity, and the item of the BoQ it goes to.
- 4Check Goes to: Found items are clearly the right ones; Look at it means several items of the BoQ could be it: confirm the one proposed (Right), choose another, or empty it for a new item; New item is made in its bill.
- 5Press Add to the BoQ.
How an item of the BoQ is found
- Only items in the same unit are considered.
- The words of the assembly item are compared with each description; an item in the bill named by the assembly (Walling, Finishings...) counts a little more.
- Found: the best fits well and clearly better than the next. Look at it: it fits, but another is close (three block walls of 150, 200 and 230mm). New item: nothing fits; a new item is made in a bill of that name, or a new bill.
- Nothing is added before every Look at it is confirmed or changed.
HodariQ's standard assemblies
| Assembly | Sizes | Items and formulas |
|---|---|---|
| Block wall with plaster and paint | L length, H height, O openings (m2), S faces (0, 1, 2) | Walling L x H - O (m2); plaster and paint S x (L x H - O) (m2); DPC L (m) |
| Strip foundation | P length, B width, D depth, F footing, BL blinding, TW wall thickness | Excavation P x B x D (m3); blinding P x B (m2); footing P x B x F (m3); walling below ground P x (D - BL - F) (m2); backfill P x (B - TW) x (D - BL - F) (m3); disposal P x B x (BL + F) + P x TW x (D - BL - F) (m3) |
| Ground floor slab on hardcore | L, W | Hardcore, anti-termite, DPM, 150mm bed, mesh: L x W (m2); edge formwork 2 x (L + W) (m) |
| Suspended slab | L, W | Slab, soffit formwork, soffit plaster and paint: L x W (m2); edges 2 x (L + W) (m) |
| Reinforced concrete columns | N number, B, D section, H height | Concrete N x B x D x H (m3); formwork N x 2 x (B + D) x H (m2) |
| Reinforced concrete beams | L total length, B, D | Concrete L x B x D (m3); formwork to sides and soffit L x (B + 2 x D) (m2) |
| Column bases | N, B, W, T base, D pit depth, WS working space | Excavation N x (B + 2 x WS) x (W + 2 x WS) x D (m3); blinding N x B x W (m2); concrete N x B x W x T (m3); formwork N x 2 x (B + W) x T (m2) |
| Room finishes | L, W, H, O openings, DW door widths | Bed and floor tiles L x W; skirting 2 x (L + W) - DW; wall plaster and paint 2 x (L + W) x H - O; gypsum ceiling and paint L x W |
| Pitched roof covering | A plan area, F slope factor, R ridges, E eaves | Sheets A x F (m2); ridge R; fascia and gutter E (m) |
| Paved road section | L, W carriageway, SH shoulder, T1 subbase, T2 base, T3 shoulder, ML marking lines | Roadbed L x (W + 2 x SH); subbase L x (W + 2 x SH) x T1; base L x W x T2; shoulders L x 2 x SH x T3; prime and surfacing L x W; markings L x ML / 1000 (km) |
| Gravel road section | L, R reserve, W, T, DR drains | Clearing L x R; roadbed L x W; gravel L x W x T; side drains L x DR |
| Pipeline in trench | L, B, D, S bedding | Excavation L x B x D; bedding L x B x S; backfill L x B x (D - S); disposal L x B x S; pipe L |
The slope factor of a roof is 1 / cos(slope): 1.04 for 15 degrees, 1.10 for 25 degrees, 1.15 for 30 degrees. The working space of column bases is 0 by default: the standard method of East Africa measures excavation net to the base.
The firm's own assemblies
- Configuration > BoQ Assemblies: duplicate a standard one to change it, or make a new one.
- Sizes asked: a letter or a few letters and figures (L, H, TW, T1; not X), the question asked, its usual value.
- Items given: the BoQ description of a new item, its unit, its formula, the bill it goes to and the words that find it.
- A formula uses figures, the letters of the sizes, + - x / and brackets: 2 x L x H, L x (B - TW) x (D - 0.05). Write x between terms (with spaces between two letters: L x H). A formula that uses anything else cannot be saved.
Good to know
A quantity that works out below zero (openings larger than the wall) stops the assembly with its item named: check the sizes.
Something unclear? Ask us on WhatsApp: we answer the same day.